Transformer Oil Gas Analysis using a Stripper Column (ASTM D3612)Aplikace | | SCION Instruments InstrumentaceGCZaměřeníPrůmysl a chemieVýrobceSCION InstrumentsKlíčová slovagases, stripper, oil, dissolved, scion, methaniser, toga, ldl, transformer, extraction, carbon, analysed, localised, summarised, conlusion, resting, vacuum, catastrophic, sparging, repeatability, headspace, porabond, equipped, interest, chances, separate, poraplot, luer, analyser, lighter, optimised, loops, instruments, brought, passes, whilst, satisfactory, levels, sample, oven, whereas, obtained, components, figures, lock, converted, failure, carrier, used, tcd
Podobná PDF
Transformer Oil Gas Analysis with the Bruker TOGA Analyzer equipped with the Bruker Headspace Sampler
2011|Bruker|Aplikace
Gases in TransformerOil AnalysisApplication Notes #283028Transformer Oil Gas Analysis with the Bruker TOGAAnalyzer equipped with the Bruker Headspace Sampler.Insulating fluids, generally mineral oils, are used intransformers. Under normal, mild conditions there isAs a result, a portion of a gas dissolved...
Klíčová slova
oil, oiltransformer, transformerbruker, brukergases, gasestoga, togastripper, stripperfill, filloff, offgas, gasbypass, bypassrepeatability, repeatabilitytcd, tcdschaffer, schafferextracted, extracteddissolved
Transformer Oil Gas Analysis via Headspace Sampling (ASTM D3612)AN0030Application NoteINTRODUCTIONTable 1 details the analytes of interest obtained froman injection of a commercial oil standard.Insulating fluids, generally mineral oils, are used intransformers. Under normal, mild conditions, there isvery little decomposition. However,...
Klíčová slova
scion, scionoil, oilrepeatability, repeatabilitytransformer, transformeroff, offfill, fillbypass, bypassonto, ontoheadspace, headspaceextraction, extractionseries, seriestcd, tcddissolved, dissolvedporous, porousmethaniser
SpecificationsStandard methods:ASTM D3612 part CFully automated Transformer Oil Gas AnalyserConfiguration:One channel instrument based on Thermo Trace 1300 GC or CompactGC,According to ASTM D 3612cPerforms better than ASTM 3612c requirementsusing microTCD, methaniser and FID.Automated injection, closed loop principle, using:Small footprint- Teledyne...
Klíčová slova
toga, togamethaniser, methaniserinstantconnect, instantconnecttcd, tcdfid, fidtransformer, transformeranalyser, analyseriec, iecautosampler, autosamplergas, gasloop, loopacetylene, acetylenefootprint, footprintoil, oilethane
Analysis of Dissolved Gas in Transformer Oil by Gas Chromatography using a Stripper Column
2008|Agilent Technologies|Aplikace
NOTICE: This document contains references to Varian.Please note that Varian, Inc. is now part of AgilentTechnologies. For more information, go towww.agilent.com/chem.Application Note SI-01298Analysis of Dissolved Gas in Transformer Oil by Gas Chromatography using a Stripper ColumnCoen Duvekot, Inze Bos and...
Klíčová slova
stripper, strippervent, ventgases, gasestoga, togamin, minchannel, channeldissolved, dissolvedporabond, porabondmethanizer, methanizeroven, ovengas, gasoil, oilfigures, figurescolumn, columnflushed