Expanding Lab Capability using Agilent’s GC/QQQ Analyzer with a New Versatile 1000-compound Pesticide MRM DatabasePrezentace | | Agilent Technologies InstrumentaceGC/MSD, GC/MS/MS, GC/QQQVýrobceAgilent TechnologiesKlíčová slovamrm, database, backflush, pesticide, analyzer, tto, epc, ultimate, sorting, inlet, backflushing, column, siignal, flow, purged, liness, noise, constant, spinach, union, absolute, responses, heavy, each, dash, transitions, factory, orange, build, allows, after, boilers, flexible, mins, time, vent, alternatives, transition, retention, ions, rts, method, reduces, run, matrix, lab, acephate, ltimate, lindane, comprehensive
Podobná PDF
A Method for the Trace Analysis of 175 Pesticides Using the Agilent Triple Quadrupole GC/MS/MS
2009|Agilent Technologies|Aplikace
A Method for the Trace Analysis of175 Pesticides Using the AgilentTriple Quadrupole GC/MS/MSApplication NoteFood SafetyAuthorsAbstractPhilip L. Wylie and Chin-Kai MengA GC/MS/MS multiple reaction monitoring (MRM) method has been developed onAgilent Technologies, Inc.the Agilent 7890A/7000A GC triple quadrupole mass spectrometer system...
Klíčová slova
inlet, inletion, iongap, gapbackflushing, backflushingtransition, transitionprecursor, precursorqqq, qqqconnections, connectionstemperature, temperaturedeconvolution, deconvolutioncontinued, continuedagilent, agilentaux, auxepc, epcacquisition
The GC/MS/MS Analyzer and the Pesticides and Environmental Pollutants MRM Database
2011|Agilent Technologies|Aplikace
The GC/MS/MS Analyzer and thePesticides and Environmental PollutantsMRM DatabaseApplication NoteFood Safety and EnvironmentalAuthorAbstractChin-Kai MengBased on an Agilent 7890A GC System and an Agilent 7000 Series Triple QuadrupoleAgilent Technologies, Inc.GC/MS, these GC/MS/MS Multiresidue Analyzers were developed to simplify a lab’s2850 Centerville...
Klíčová slova
database, databasemrm, mrmcompound, compoundconstant, constanttransitions, transitionsspinach, spinachmatrix, matrixris, risincluded, includedquechers, quecherslist, listorange, orangeinterference, interferencedeuterated, deuteratedpear
Extracting More Analytes from Complex Samples using Agilent’s GC/TQ and GC/Q-TOF
|Agilent Technologies|Prezentace
Extracting MoreAnalytes from ComplexSamples using Agilent’sGC/TQ and GC/Q-TOFGC/TQ (Triple Quad):Chin-Kai (Kai) Meng, PhDSSeniorApplication ChemistCGC/Q-TOF (Quad-Time-of-Flight):Terry L. Sheehan, PhDGC/MS Marketing ManagerExtracting More AnalytesffromCComplexl SamplesSl usingiAgilent’s Pesticide GC/TQAnalyzery-- “Ready to Go” Analyzer basedon the most comprehensiveMRM databaseReady to use Fast Track Analyzers…...
Klíčová slova
tof, tofppm, ppmmass, masscentroid, centroidtocopherol, tocopherolaccurate, accuratemrm, mrmtargets, targetspesticide, pesticideion, ionresolution, resolutionresolving, resolvingformula, formulabetter, betterdatabase
A Fast and Robust GC/MS/MS Analysis of 203 Pesticides in 10 Minutes in Spinach
2022|Agilent Technologies|Aplikace
Application NoteFood & Beverage TestingA Fast and Robust GC/MS/MSAnalysis of 203 Pesticides in10 Minutes in SpinachAuthorsAbstractAnastasia A. Andrianova,Bruce D. Quimby,and Limian ZhaoAgilent Technologies, Inc.This application note describes two approaches for achieving robust, multiresiduepesticide analysis in 10 minutes by GC/MS/MS, while...
Klíčová slova
retenion, retenionmidcolumn, midcolumninlet, inletmrm, mrmpsd, psdpesticides, pesticidesbackflush, backflushconfigurations, configurationstimes, timesretention, retentionagilent, agilentspinach, spinachrobustness, robustnesspuu, puubackflushing