Improved Performance And Dynamic Range For EPA Method TO-15 using the Entech 7200 and Agilent 7890B/5977 GCMS
Aplikace | 2015 | ENTECHInstrumentace
GC/MSD, Termální desorpce, Příprava vzorků, GC/SQ
ZaměřeníŽivotní prostředí
VýrobceAgilent Technologies, ENTECH
Klíčová slovatrap, canister, canisters, air, trapping, low, compounds, preconcentration, volume, which, next, silonite, focusing, inertness, water, sample, calibration, years, when, from, than, system, improved, keeps, using, been, saturation, volumes, recovery, every, concentration, management, adsorbent, much, dynamic, has, final, wider, standards, even, accidently, cold, gcms, output, systems, isolation, perfected, possible, stage, process
Podobná PDF
Improved Performance And Dynamic Range For EPA Method TO-15 using the Entech 7200 and Thermo Scientific ISQ QD GCMS
|Thermo Fisher Scientific|Aplikace
Improved Performance And Dynamic Range For EPA Method TO-15 using the Entech 7200 and Thermo Scientific ISQ QD GCMS INSTRUMENTS INC. Application Note: A-3736-02 Authors Doug Markle Chris Casteel Tom Robinson Dan Cardin Entech Instruments, Inc. Simi Valley, CA 93065…
Klíčová slova
canisters, canisterstrapping, trappingsilonite, siloniteair, aircanister, canistertrap, trapisq, isqpreconcentration, preconcentrationvolume, volumeconcentration, concentrationsample, sampleaccu, accuvery, veryentech, entechgcms
Improved Performance And Dynamic Range For EPA Method TO-15 using the Entech 7200 and Shimadzu QP2010 Ultra GCMS
|Shimadzu|Aplikace
Improved Performance And Dynamic Range For EPA Method TO-15 using the Entech 7200 and Shimadzu QP2010 Ultra GCMS INSTRUMENTS INC. Application Note: A-3736-01 Authors Doug Markle Chris Casteel Tom Robinson Dan Cardin Entech Instruments, Inc. Simi Valley, CA 93065 Abstract…
Klíčová slova
silonite, siloniteair, airtrapping, trappingaccidently, accidentlycanister, canistersample, sampletrap, trapvolume, volumeinert, inertaccu, accuentech, entechlittle, littlecompounds, compoundscanisters, canisterskeeps
Fast US EPA TO15 Analysis Providing Higher Productivity using the new Entech 7200A and Agilent 7890B/5977 GCMS
2018|Agilent Technologies|Aplikace
Fast US EPA TO15 Analysis Providing Higher Productivity using the new Entech 7200A and Agilent 7890B/5977 GCMS Application Note: A-3742-01 Authors Daniel B. Cardin Tom Robinson Victoria L. Noad Entech Instruments Simi Valley, CA 93065 Introduction Canister sampling and analysis…
Klíčová slova
tert, tertether, etherchloride, chlorideentech, entechbutyl, butylvinyl, vinylbromoethene, bromoethenemethyl, methyltrichlorotrifluoroethane, trichlorotrifluoroethaneisopropyl, isopropylpreconcentrators, preconcentratorsethyl, ethylacetate, acetatebenzene, benzenepropene
Expanding the Molecular Weight Range of Whole Air Sampling with Stainless Steel Canisters using Active SPME Sample Preparation and GCMS Analysis
2010|Agilent Technologies|Aplikace
Expanding the Molecular Weight Range of Whole Air Sampling with Stainless Steel Canisters using Active SPME Sample Preparation and GCMS Analysis Application Note: A-3732-03 Authors Chris Casteel Dan Cardin Entech Instruments, Inc. Simi Valley, CA 93065 Abstract A new preconcentration…
Klíčová slova
spme, spmecanisters, canisterscanister, canisterthermal, thermalbakeout, bakeouttrap, trapdesorb, desorbrotary, rotaryactive, activecompounds, compoundsair, airtenax, tenaxdean, deaneliminated, eliminatedthermally