Improved Performance And Dynamic Range For EPA Method TO-15 using the Entech 7200 and Thermo Scientific ISQ QD GCMS
Aplikace | | ENTECHInstrumentace
GC/MSD, Termální desorpce, Příprava vzorků, GC/SQ
ZaměřeníŽivotní prostředí
VýrobceThermo Fisher Scientific, ENTECH
Klíčová slovacanisters, trapping, silonite, air, canister, trap, isq, preconcentration, volume, concentration, sample, accu, very, gcms, entech, low, compounds, improved, from, keeps, calibration, using, inert, saturation, volumes, next, analysis, which, much, management, laboratories, high, than, accidently, exactness, markle, even, cold, today, should, water, achieved, output, when, casteel, performance, isolation, cardin, greatly, recovery
Podobná PDF
Improved Performance And Dynamic Range For EPA Method TO-15 using the Entech 7200 and Shimadzu QP2010 Ultra GCMS
|Shimadzu|Aplikace
Improved Performance And Dynamic Range For EPA Method TO-15 using the Entech 7200 and Shimadzu QP2010 Ultra GCMS INSTRUMENTS INC. Application Note: A-3736-01 Authors Doug Markle Chris Casteel Tom Robinson Dan Cardin Entech Instruments, Inc. Simi Valley, CA 93065 Abstract…
Klíčová slova
silonite, siloniteair, airaccidently, accidentlytrapping, trappingcanister, canistersample, sampletrap, trapvolume, volumeinert, inertaccu, accuentech, entechlittle, littlecompounds, compoundscanisters, canisterskeeps
Improved Performance And Dynamic Range For EPA Method TO-15 using the Entech 7200 and Agilent 7890B/5977 GCMS
2015|Agilent Technologies|Aplikace
Improved Performance And Dynamic Range For EPA Method TO-15 using the Entech 7200 and Agilent 7890B/5977 GCMS Application Note: A-3737-01 Authors Tom Robinson Dan Cardin Entech Instruments, Inc. Simi Valley, CA 93065 Abstract Canister sampling and analysis for measurement of…
Klíčová slova
trap, trapcanister, canistercanisters, canistersair, airtrapping, trappinglow, lowcompounds, compoundspreconcentration, preconcentrationvolume, volumewhich, whichnext, nextinertness, inertnesssilonite, silonitefocusing, focusingsample
Fast US EPA TO15 Analysis Providing Higher Productivity using the new Entech 7200A and Agilent 7890B/5977 GCMS
2018|Agilent Technologies|Aplikace
Fast US EPA TO15 Analysis Providing Higher Productivity using the new Entech 7200A and Agilent 7890B/5977 GCMS Application Note: A-3742-01 Authors Daniel B. Cardin Tom Robinson Victoria L. Noad Entech Instruments Simi Valley, CA 93065 Introduction Canister sampling and analysis…
Klíčová slova
tert, tertether, etherchloride, chlorideentech, entechbutyl, butylvinyl, vinylmethyl, methylbromoethene, bromoethenetrichlorotrifluoroethane, trichlorotrifluoroethaneisopropyl, isopropylpreconcentrators, preconcentratorsethyl, ethylbenzene, benzeneacetate, acetatepropene
Expanding the Molecular Weight Range of Whole Air Sampling with Stainless Steel Canisters using Active SPME Sample Preparation and GCMS Analysis
2010|Agilent Technologies|Aplikace
Expanding the Molecular Weight Range of Whole Air Sampling with Stainless Steel Canisters using Active SPME Sample Preparation and GCMS Analysis Application Note: A-3732-03 Authors Chris Casteel Dan Cardin Entech Instruments, Inc. Simi Valley, CA 93065 Abstract A new preconcentration…
Klíčová slova
spme, spmecanisters, canisterscanister, canisterthermal, thermaldesorb, desorbtrap, trapbakeout, bakeoutrotary, rotarycompounds, compoundsactive, activetenax, tenaxair, airdean, deaneliminated, eliminatedthermally