US EPA Method 524.3 with the Teledyne Tekmar Atomx XYZ and the Thermo Scientific™ TRACE™ 1310 GC and ISQ™ LT MS System
Aplikace | 2019 | Teledyne LABSInstrumentace
GC/MSD, Purge and Trap, GC/SQ
ZaměřeníŽivotní prostředí
VýrobceThermo Fisher Scientific, Teledyne LABS
Klíčová slovatemp, bake, purge, rinse, lpir, upir, sweep, tert, xyz, ether, atomx, desorb, precision, accuracy, mrl, table, methanol, mdl, iii, time, variable, ppb, butylbenzene, flow, confirmation, needle, volume, condensate, linearity, butyl, sparge, dry, rinses, teledyne, tekmar, water, chloride, sample, amyl, ethyl, glass, off, pre, drain, methyl, vessel, compound, vocs, calibration, heater
Podobná PDF
US EPA Method 524.4 with the Tekmar Atomx XYZ and the Thermo Scientific™ TRACE™ 1310 GC and ISQ™ 7000 MS System with an ExtractaBrite Source
2020|Thermo Fisher Scientific|Aplikace
APPLICATION NOTE: TECHNOLOGY: INDUSTRY: AN2005 P+T VOC ENV US EPA Method 524.4 with the Tekmar Atomx XYZ and the Thermo Scientific™ TRACE™ 1310 GC and ISQ™ 7000 MS System with an ExtractaBrite Source Amy Nutter, Applications Chemist; Teledyne Tekmar P…
Klíčová slova
temp, tempbake, bakepurge, purgerinse, rinsetert, tertppb, ppbupir, upirlpir, lpirsweep, sweepether, etheratomx, atomxdesorb, desorbtime, timeprecision, precisiondemonstration
US EPA Method 524.4 using the Teledyne Tekmar Atomx XYZ and Thermo Scientific™ ISQ™ 7000 Mass Spectrometry (MS) System Coupled with a Thermo Scientific™ TRACE™ 1310 Gas Chromatograph (GC)
2020|Thermo Fisher Scientific|Aplikace
APPLICATION NOTE: TECHNOLOGY: INDUSTRY: AN2002 P+T VOC ENV US EPA Method 524.4 using the Teledyne Tekmar Atomx XYZ and Thermo Scientific™ ISQ™ 7000 Mass Spectrometry (MS) System Coupled with a Thermo Scientific™ TRACE™ 1310 Gas Chromatograph (GC) Amy Nutter, Applications…
Klíčová slova
temp, tempbake, bakepurge, purgerinse, rinseavg, avgsweep, sweeptert, tertether, etheratomx, atomxdesorb, desorbppb, ppbupir, upirlpir, lpirtime, timexyz
US EPA Method 524.3 - Atomx XYZ and Agilent 7890B GC/5977A MS
2018|Agilent Technologies|Aplikace
APPLICATION NOTE: TECHNOLOGY: INDUSTRY: AN1802 P+T VOC ENV US EPA Method 524.3 - Atomx XYZ and Agilent 7890B GC/5977A MS Amy Nutter, Applications Chemist; Teledyne Tekmar P a g e |1 Abstract US EPA Method 524.3 was used to determine…
Klíčová slova
temp, tempbake, bakepurge, purgerinse, rinselpir, lpirupir, upirsweep, sweeptert, tertether, etheratomx, atomxdesorb, desorbprecision, precisionaccuracy, accuracymrl, mrltable
US EPA Method 524.3 with the Teledyne Tekmar Atomx XYZ and Thermo Scientific™ TRACE™ 1310 GC and ISQ™ 7000 MS with an Advanced Electron Ionization (AEI) Source
2018|Thermo Fisher Scientific|Aplikace
APPLICATION NOTE: TECHNOLOGY: INDUSTRY: AN1805 P+T VOC ENV US EPA Method 524.3 with the Teledyne Tekmar Atomx XYZ and Thermo Scientific™ TRACE™ 1310 GC and ISQ™ 7000 MS with an Advanced Electron Ionization (AEI) Source Amy Nutter, Applications Chemist; Teledyne…
Klíčová slova
temp, tempbake, bakepurge, purgerinse, rinseaccuracy, accuracylpir, lpirupir, upirsweep, sweeptert, tertmidpoint, midpointether, etheratomx, atomxdesorb, desorbtime, timeprecision