Automated SPE and Fast GC-ECD Analysis of PCBs in Waste OilAplikace | 2008 | GERSTEL InstrumentaceGC, Příprava vzorkůZaměřeníPotraviny a zemědělstvíVýrobceAgilent Technologies, GERSTELKlíčová slovagerstel, pcbs, tray, cartridge, waste, modular, spe, accelarated, analysis, ecd, response, fast, sample, prepbuilder, bcr, vials, ppm, mach, onto, germany, oil, stations, elution, weigh, served, column, door, preparation, containing, solid, capped, capillary, holding, standard, recovery, using, pull, filling, official, ied, tif, fic, mounted, capillaries, district, pudong, llp, sys, awarded, pcb
Podobná PDF
Ultra-Fast Determination of the Hydrocarbon Oil Index by Gas Chromatography using a Modular Accelerated Column Heater (MACH)
2006|Agilent Technologies|Aplikace
AppNote 6/2006Ultra-Fast Determination of theHydrocarbon Oil Index by GasChromatography using a ModularAccelerated Column Heater (MACH)Andreas HoffmannGERSTEL GmbH & Co.KG, Eberhard-Gerstel-Platz 1,D-45473 Mülheim an der Ruhr, GermanyBart Tienpont, Frank David, Pat SandraResearch Institute for Chromatography, Kennedypark 26,B-8500 Kortrijk, BelgiumKEYWORDSUltra Fast GC,...
Klíčová slova
mach, machhoi, hoioil, oilmineral, mineraldiesel, dieselhydrocarbon, hydrocarbongerstel, gerstelfast, fastmodular, modularaccelerated, acceleratedindex, indexheater, heatermixture, mixtureultra, ultrawire
Evaporative Concentration of Substances Listed in the European Water Framework Directive (2000/60/EC and 2008/105/EC). A Performance Comparison Between an Automated System and a Manual System
2012|Agilent Technologies|Aplikace
AppNote 7/2012Evaporative Concentration ofSubstances Listed in the EuropeanWater Framework Directive(2000/60/EC and 2008/105/EC). APerformance Comparison Betweenan Automated System and a ManualSystem.Susanne SperlingGerstel GmbH & Co. KG, Eberhard-Gerstel-Platz 1,D-45473 Mülheim an der Ruhr, GermanyKEYWORDSmVap,Evaporation, SPE, DPXABSTRACTHaving to reach ever lower limits of...
Klíčová slova
mvap, mvapevaporation, evaporationgerstel, gerstelhch, hchautomated, automatedbenzo, benzosteps, stepssolvent, solventframework, frameworkmanual, manualmps, mpscommercially, commerciallysample, samplestation, stationfluoranthene
GC/MS Analysis of PCBs in Waste Oil Using the Backflush Capability of the Agilent QuickSwap Accessory
2007|Agilent Technologies|Aplikace
GC/MS Analysis of PCBs in Waste OilUsing the Backflush Capability of theAgilent QuickSwap AccessoryApplicationEnvironmentalAuthorsFrank DavidResearch Institute for ChromatographyPres. Kennedypark 268500 KortrijkBelgiumMatthew S. KleeAgilent Technologies2850 Centerville RoadWilmington, DE 19808USAAbstractPolychlorinated biphenyls (PCBs) in waste oil are typically analyzed by GC-ECD or GC/MS...
Klíčová slova
backflush, backflushquickswap, quickswapscan, scanpcbs, pcbssim, simwaste, wasteoil, oilpressure, pressurepcb, pcbtics, ticsagilent, agilentchromatograms, chromatogramsprogram, programdata, dataafter
Automated Clean-up of PCB extracts from Waste Oil using the Agilent 7696A Sample Prep WorkBench
2011|Agilent Technologies|Aplikace
Automated Clean-up of PCB extractsfrom Waste Oil using the Agilent 7696ASample Prep WorkBenchApplication NoteAutomated Sample PreparationAuthorsAbstractFrank David, Bart Tienpont, andSolid waste, including petroleum based waste oils, transformer oil or mineral oil areKarine Jacqscreened for the presence of polychlorinated biphenyls (PCBs)....
Klíčová slova
waste, wasteoil, oilminiaturized, miniaturizedfraction, fractionacidified, acidifiedadsorbents, adsorbentsbind, bindsolute, solutesilica, silicaallows, allowsvortex, vortexpolar, polarmineral, mineralpcb, pcbagilent