Using Alternative Carrier Gas for US EPA 524.3
Aplikace | 2013 | Teledyne LABSInstrumentace
GC/MSD, Purge and Trap, GC/SQ
ZaměřeníŽivotní prostředí
VýrobceThermo Fisher Scientific, Teledyne LABS
Klíčová slovatemp, bake, tert, rinse, ether, purge, butylbenzene, tic, butyl, sweep, chloride, desorb, time, methanol, condensate, brodichloromethane, ethylmethacrylate, difluorochloromethane, teledyne, tekmar, flow, needle, prepurge, value, volume, off, methyl, carbon, atomx, pentachloroethane, sample, etbe, sparge, isopropyltoluene, diisopropyl, dry, rinses, allyl, tetrachloroethylene, dichlorodifluoromethane, bromobenzene, trichlorofluoromethane, bromochloromethane, isopropylbenzene, trichloroethylene, trichloroethene, glass, chloromethane, dibromochloromethane, propylbenzene
Podobná PDF
US EPA Method 524.3 with the Teledyne Tekmar Atomx XYZ and Thermo Scientific™ TRACE™ 1310 GC and ISQ™ 7000 MS with an Advanced Electron Ionization (AEI) Source
2018|Thermo Fisher Scientific|Aplikace
APPLICATION NOTE: TECHNOLOGY: INDUSTRY: AN1805 P+T VOC ENV US EPA Method 524.3 with the Teledyne Tekmar Atomx XYZ and Thermo Scientific™ TRACE™ 1310 GC and ISQ™ 7000 MS with an Advanced Electron Ionization (AEI) Source Amy Nutter, Applications Chemist; Teledyne…
Klíčová slova
temp, tempbake, bakepurge, purgerinse, rinseaccuracy, accuracylpir, lpirupir, upirsweep, sweeptert, tertmidpoint, midpointatomx, atomxether, etherdesorb, desorbtime, timeprecision
USEPA Method 524.4 Using the Teledyne Tekmar Atomx and Thermo Scientific™ GC/MS System with New Helium Saver Module
2016|Thermo Fisher Scientific|Aplikace
USEPA Method 524.4 Using the Teledyne Tekmar Atomx and Thermo Scientific™ GC/MS System with New Helium Saver Module Application Note Roger Bardsley, Applications Chemist; Teledyne Tekmar P a g e |1 Abstract Increasing concerns over the availability of helium, and…
Klíčová slova
temp, tempbake, bakepurge, purgerinse, rinsesweep, sweeptert, tertether, etherdesorb, desorbcondensate, condensateatomx, atomxrinses, rinsestime, timesample, samplevariable, variablemethanol
US EPA Method 524.3 with the Teledyne Tekmar Atomx XYZ and the Thermo Scientific™ TRACE™ 1310 GC and ISQ™ LT MS System
2019|Thermo Fisher Scientific|Aplikace
APPLICATION NOTE: TECHNOLOGY: INDUSTRY: AN1907 P+T VOC ENV US EPA Method 524.3 with the Teledyne Tekmar Atomx XYZ and the Thermo Scientific™ TRACE™ 1310 GC and ISQ™ LT MS System Amy Nutter, Applications Chemist; Teledyne Tekmar P a g e…
Klíčová slova
temp, tempbake, bakepurge, purgerinse, rinselpir, lpirupir, upirsweep, sweeptert, tertxyz, xyzatomx, atomxether, etherdesorb, desorbprecision, precisionaccuracy, accuracymrl
US EPA Method 524.3 - Atomx XYZ and Agilent 7890B GC/5977A MS
2018|Agilent Technologies|Aplikace
APPLICATION NOTE: TECHNOLOGY: INDUSTRY: AN1802 P+T VOC ENV US EPA Method 524.3 - Atomx XYZ and Agilent 7890B GC/5977A MS Amy Nutter, Applications Chemist; Teledyne Tekmar P a g e |1 Abstract US EPA Method 524.3 was used to determine…
Klíčová slova
temp, tempbake, bakepurge, purgerinse, rinselpir, lpirupir, upirsweep, sweeptert, tertatomx, atomxether, etherdesorb, desorbprecision, precisionaccuracy, accuracymrl, mrltable