GCMS
Další informace
WebinářeO násKontaktujte násPodmínky užití
LabRulez s.r.o. Všechna práva vyhrazena. Obsah dostupný pod licencí CC BY-SA 4.0 Uveďte původ-Zachovejte licenci.

Using Analyte Protectants and Solvent Selection to Maximize the Stability of Organophosphorus Pesticides during GC/MS Analysis

Aplikace | 2013 | Agilent TechnologiesInstrumentace
GC/MSD, GC/MS/MS, GC/QQQ
Zaměření
Životní prostředí, Potraviny a zemědělství
Výrobce
Agilent Technologies
Klíčová slova
PDF verze ke stažení a čtení
 

Podobná PDF

Toggle
Analysis of Fruit and Vegetable Pesticides by GC/MS/MS Using Agilent Inert Flow Path Application Note Food Testing and Agriculture Author Abstract Limian Zhao and Mike Szelewski The Agilent Inert Flow Path (IFP) solution was evaluated and validated thoroughly Agilent Technologies,…
Klíčová slova
ifp, ifpreponses, reponsesagilent, agilentcounts, countsstrawberry, strawberrydeactivated, deactivatedpesticide, pesticidesandwiched, sandwichedhos, hospesticides, pesticidesinert, inertmatrix, matrixonion, onionrelative, relativeinjection
Multiresidue Pesticide Analysis with the Agilent Intuvo 9000 GC and Agilent 7000 Series Mass Spectrometer Application Note Author Abstract Rebecca Veeneman, PhD and This Application Note shows an evaluation of pesticides in seven different Joan Stevens, PhD matrices for the…
Klíčová slova
ifo, ifointuvo, intuvolta, ltaflua, fluaxali, xalilin, lingenogrinder, genogrindernid, nidflu, fluacr, acrlon, lonrecovery, recoveryldr, ldrtea, teawere
Advantages of Reversed Sandwich Injection for Pesticide Residue Analysis Application Note Author Abstract Jessica Westland This application note demonstrates the use of the Agilent 7693A ALS system’s Agilent Technologies, Inc. Reversed 3-Layer Switch sandwich injection functionality for the analysis of…
Klíčová slova
matrix, matrixlayer, layerorp, orpsandwich, sandwichbottom, bottomdrawn, drawnmatched, matchednfl, nfltop, topmire, mirepesticides, pesticidespim, pimyri, yriiph, iphthre
Improved GC/MS Analysis of Tomato Pesticides with Agilent Deactivated Silica Tubing Agilent Ultimate Plus Deactivated Fused Silica Tubing for Guard Columns Application Note Food Safety Authors Abstract Yun Zou and Andy Zhai Agilent Ultimate Plus deactivated fused silica tubing was…
Klíčová slova
deactivated, deactivatedtubing, tubingultimate, ultimateguard, guardplus, plusagilent, agilentcolumn, columnfused, fusedsilica, silicasupplier, supplierpesticides, pesticidestomato, tomatomethyl, methylddv, ddvparathion
Další projekty
Sledujte nás
Další informace
WebinářeO násKontaktujte násPodmínky užití
LabRulez s.r.o. Všechna práva vyhrazena. Obsah dostupný pod licencí CC BY-SA 4.0 Uveďte původ-Zachovejte licenci.